Ceiling.Create(Document, IList<CurveLoop>, ElementId, ElementId)
Description:
Creates a new instance of ceiling within the project.
Creates a new instance of ceiling within the project.
Remarks:
To validate curve loop profile use BoundaryValidation.
To validate curve loop profile use BoundaryValidation.
Overloads (2):
Create(Document,IList[CurveLoop],ElementId,ElementId)
-
documentThe document in which the new ceiling is created.
-
IList<CurveLoop>curveLoopsAn array of planar curve loops that represent the profile of the ceiling.
-
ceilingTypeIdId of the ceiling type to be used by the new ceiling. If InvalidElementId is passed, the default type will be used.
-
levelIdId of the level on which the ceiling is to be placed.
-
The ElementId levelId is not a Level. -or- The ElementId ceilingTypeId does not correspond to a CeilingType. -or- The input curve loops cannot compose a valid boundary, that means: the "curveLoops" collection is empty; or some curve loops intersect with each other; or each curve loop is not closed individually; or each curve loop is not planar; or each curve loop is not in a plane parallel to the horizontal(XY) plane; or input curves contain at least one helical curve. -or- Input curves build invalid sketch. -or- Failed to create curve elements.
-
A non-optional argument was null
-
Cannot generate a sketch. -or- Failed to create new element.
-
The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements). -or- The document is being loaded, or is in the midst of another sensitive process.
-
The document has no open transaction.
No comments yet. Start the discussion.